| Item | Type | Specifications | Full Capacity | Sealing Method | Cable Ports | Applicable Cable Diameter | Installation Method | |
|---|---|---|---|---|---|---|---|---|
| H × W× D (mm) | Bundle | Ribbon | ||||||
| Optical Fibre Closure (Horizontal) |
GJS-6020 |
474 × 222 × 124 |
96 |
144 |
Mechanical seal |
2 ingress and 2 egress |
φ8 - 16mm |
Overhead, wall-mounted, direct burial |
|
GJS-6007 |
388 × 185 × 104 |
96 |
144 |
Mechanical seal |
3 ingress and 3 egress |
4 holes: φ8 - 13 mm, 2 holes: φ8 - 16 mm |
Overhead, wall-mounted | |
|
GJS-6012 |
560 × 245 × 180 |
384 |
432 |
Mechanical seal |
8 ingress and 8 egress |
2 holes: φ2 - 23 mm, 2 holes: φ2 - 20 mm 4 holes: φ4 - 16 mm, 8 holes: φ8 - 14 mm |
||
|
GJS09-6407 |
455 × 180 × 120 |
96 |
-- |
Mechanical seal |
2 ingress and 2 egress |
φ10 - 17.5mm |
||
|
GPJ09-6806-B |
474 × 201 × 150 |
144 |
432 |
Mechanical seal |
2 ingress and 2 egress |
φ10 - 17.5mm |
||
|
GTJA209-1 |
460 × 180 × 108 |
96 |
-- |
Mechanical seal |
2 ingress and 2 egress |
φ7 - 18mm |
||
|
Product Series |
GJS series, GPJ09 series, GTJA series |
|---|---|
|
Protection Level |
IP68 |
|
Operating Temperature |
–40°C to +60°C |
|
Storage Temperature |
–40°C to +70°C |
| Atmospheric Pressure |
70 kPa to 106 kPa |
| Leak Tightness at Ambient Temperature |
100 kPa internal pressure maintained for 24 h |
| Temperature Cycle |
Appearance and leak tightness maintained after 20 temperature cycles (–40°C to +65°C) under 60 kPa ±5 kPa |
| Pressure Resistance |
Able to bear 2,000 N/100 mm pressure |
| Tensile Strength |
Able to bear axial tension ≥ 800 N |
| Bend Resistance |
Able to bear bending force of 150 N for ten ±45° bending cycles |
| Service Life |
Over 20 years |
| Standards Compliance |
Compliant with Chinese national standards, including YD/T814.1-2004 and YD/T814.2-2005, and international standards, including ITU L.13-2003 and UL 94 |